Cause |
|
Remedy |
| |
Incorrect
rotation of pump |
|
Reverse
immediately |
| |
Oil level
in reservoir too low |
|
Top up
with correct filtered fluid |
| |
Loose
suction line connection |
|
Check/tighten
pipe fittings |
| |
Suction
pipe or strainer blocked |
|
Clean if
possible or replace |
| |
Incorrect
viscosity of fluid |
|
Check
with pump makers specifications |
| |
Air breather
blocked |
|
Check and
clear |
| |
Pump
parts broken |
|
Replace
or repair if possible |
| |
Relief
valve jammed open |
|
Clean and
adjust valve, replace if neccesary |
| |
Pump
speed to low |
|
Check
speed with makers modifications |
| |
Loss of
accumulator precharge |
|
Check pressure
against design specification |
| |
Incomplete
valve action |
|
Isolate
valve and check operation |
| |
Incorrect
assembly, broken drive coupling |
|
Rectify |
| |
Incorrect
pump setting |
|
Check
and adjust if possible |
| |
Blocked
filter |
|
Clean if
possible or replace |
| |
Cause |
|
Remedy |
| |
Is there
a lack of delivery |
|
Check with
Lack of Delivery chart |
| |
Relief
valve set too low |
|
Isolate
system and check relief valve |
| |
Relief
valve held open |
|
Clean and
adjust valve |
| |
Is oil
returning to tank through a valve |
|
Check valve
operation |
| |
Are valves
leaking internally |
|
Isolate
valves and check operation |
| |
Are there
any external leaks |
|
Tighten
fittings and check components |
| |
Normally
closed valves stuck open |
|
Clean and
check system for contamination |
| |
Is pump
casing loose |
|
Tighten
case to correct torque |
| |
Are any
oil line pipes blocked |
|
Clear blockage |
| |
Incorrect
assembly, broken drive coupling |
|
Rectify |
| |
Pump failure
due to fatigue, contamination, pressure overload, etc. |
|
Check pump
and repair if possible, if not replace the pump |
| |
Cause |
|
Remedy |
| |
Suction
line or strainer blocked |
|
Clean if
possible or replace |
| |
Aeration
in suction line |
|
Check/tighten
pipe fittings |
| |
Is pump
casing loose |
|
Tighten
case to correct torque |
| |
Restriction
in pump passages |
|
Check and
clear obstruction |
| |
Trapped
air in fluid |
|
Check components,
tighten pipe fittings, bleed system if neccessary |
| |
Breather
blocked |
|
Check and
clear |
| |
Pump speed
excessive |
|
Check speed
with makers recommendations |
| |
Incorrect
viscosity of fluid |
|
Check ambient
conditions and design specification |
| |
Misalignment
of drive coupling |
|
Re-align |
| |
Filter
too small |
|
Check flow
and pressure drop |
| |
Faulty
sticking valve |
|
Isolate
valve and check operation, replace or repair if possible |
| |
Accumulator
surges |
|
Check accumulator
precharge and correct functioning of loading valve |
| |
Loose return
pipes under tank lid |
|
Check/tighten
pipe fittings |
| |
Pipework
too small |
|
Check with
design specification |
| |
Intermittent
electrical supply |
|
Check for
correct supply |
| |
Cause |
|
Remedy |
| |
Excessive
pressure |
|
Check relief
valve setting |
| |
Seizure
due to lack of fluid |
|
See Lack
of Delivery chart |
| |
Dirt wedged
in clearances |
|
Check filters
and fluid condition |
| |
Fracture
of body due to pressure overload |
|
Check relief
valve setting |
| |
Pressure
surges |
|
Check accumulator
precharge, valve settings, load and circuit design |
| |
Failure
of control valves |
|
Replace
or repair valve |
| |
Cavitation
aeration |
|
Check fluid
lines to tank and suction pipe |
| |
Dirt materials
in fluid |
|
Check filter
and fluid condition |
| |
Incorrect
viscosity of fluid |
|
Check temperature
and viscosity with design specification |
| |
Excessive
pressure over-rated |
|
Check relief
valve setting |
| |
Misalignment
of drive coupling |
|
Re-align |
| |
Intensification
fluctuating load causing reverse flow |
|
Check load
against design specification and correct functioning of valves |
| |
Cause |
|
Remedy |
| |
Incorrect
viscosity of fluid |
|
Replace
with oil of correct viscosity |
| |
High ambient
temperature |
|
Check fluid
temperature around system |
| |
Worn pump |
|
Replace |
| |
Failure
of the cooler |
|
Repair
or replace |
| |
Oil level
in reservoir to low |
|
Top up
with correct filtered fluid |
| |
Insufficient
ventilation of power unit |
|
Check position
of power unit and move if neccessary |
| |
Incorrect
relief valve setting |
|
Isolate
valve and check operation, adjust if neccessary |